Kaltra Introduces New Downward-Spraying Distribution Technology to Boost Microchannel Evaporator Performance

Trending...
Microchannel Evaporator Kaltra GmbH
ALTMUNSTER, Austria - ColoradoDesk -- Kaltra has announced the development of a new refrigerant distribution technology that significantly improves the performance of microchannel evaporators — one of the most critical components in modern cooling and heat pump systems.

The Challenge: Uneven Refrigerant Flow

In microchannel evaporators, cooling efficiency depends on how evenly refrigerant is distributed across dozens of parallel microchannels. When the refrigerant enters the inlet header in a two-phase state (liquid and vapor), the heavier liquid naturally settles at the bottom while the lighter vapor rises to the top.

This separation causes uneven feeding of the microchannels: some channels receive mostly vapor, others too much liquid. The result is reduced heat transfer efficiency, unstable operation, and significant performance losses.

More on Colorado Desk
In practical terms:
  • Evaporators without any internal distributor can lose 25–35% of performance due to severe maldistribution.
  • Systems equipped with conventional lateral-spraying distributors typically reduce losses, but still experience 10–15% performance degradation.

The Solution: Downward-Spraying Distributor (DSD)

To address this issue, Kaltra developed a new Downward-Spraying Distributor (DSD) architecture.

Instead of injecting refrigerant sideways inside the header — as in traditional designs — the DSD injects refrigerant vertically downward through precisely calibrated openings. This seemingly simple change produces a powerful effect:
  • The downward spray works with gravity rather than against it.
  • Liquid refrigerant is actively directed toward the lower region of the header.
  • High-velocity jets create turbulence and fine mixing.
  • Liquid and vapor phases are blended more evenly before entering the microchannels.

By mechanically disrupting natural phase separation, the DSD ensures that each microchannel receives a more consistent liquid–vapor mixture.

More on Colorado Desk
Near-Ideal Performance Achieved

Testing confirmed that evaporators equipped with Kaltra's DSD technology demonstrate performance losses as low as 1–3%, approaching ideal distribution conditions.

The system also maintains high distribution uniformity:
  • At coil inclination angles up to 30°
  • At inlet vapor qualities below 0.4
  • Under realistic operating and installation conditions

Compared to conventional designs, the DSD concept represents a major improvement in evaporator stability, efficiency, and surface utilization.

Raising the Standard for Microchannel Technology

By solving one of the fundamental challenges of two-phase refrigerant flow inside horizontal headers, Kaltra's new distributor technology sets a new benchmark for microchannel heat exchanger performance.

The development reinforces Kaltra's commitment to advancing thermal management solutions through practical engineering innovation and measurable performance gains.

Source: Kaltra GmbH